Latest Products
SPECIFICATION
![]() | FEATURES:
|
|
OUTPUT SPECIFICATION Input Voltage: Typ. 90-264Vac. Power Factor Correction: Meet Harmonic Correction IEC 61000-3-2.Power Factor typ. 0.97-0.98. Input Connector: Positronic 47-pin PCIH47M400A1. Input Frequency: 47-63Hz. Inrush Current: 8.66Arms @ 230Vac. Input Current: 2.5A @115Vac/1.18A @230Vac. Dielectric Withstand: Meet IEC 60950-1 regulation. EMI: Meet EN 55022 / FCC Class A. Hold-up Time: 18.4mS @115Vac, 20.8mS @230Vac. Earth Leakage: Less than 0.64mA @230Vac. Remote ON/OFF: Available at [INH#] & [EN#] pins. Status LED: <Green> means valid input voltage. <Amber> means a critical fault. Thermal Protection (OTP): Installed NTC and thermostat for thermal sensor at [DEG#] pin. |
INPUT SPECIFICATION Output Voltage: See Ratings Chart. Output Current: See Ratings Chart. Output Wattage: Typ. 200W continuous. Output Connector: Positronic 47-pin PCIH47M400A1. Line Regulation: Typ. 0.2%. Load Regulation: Typ. ±1%. Noise & Ripple: Typ. 1% peak to peak or 55mV, whichever is greater. OVP: Built-in at all outputs. Adjustability: Available at VO1,2,3 & 4. Remote Sensing: Available at VO1,VO2,VO3 & VO4. Hot-Swap: Available. N+1 Redundancy: Installed with internal OR-ing diodes at all outputs for N+1 redundancy operation. Current Sharing: Third-wire current sharing at VO1,2,3 & 4. Over Current Protection (OCP): Installed at each rail. DC OK: Available at VO1,2,3,4 & 5. Overload Protection (OLP): Fully protected against output overload or short circuit. Typical 120-150% max. load. Consult the factory for special OLP setting. |
|
GENERAL SPECIFICATION Efficiency: Typ. 67-69 %. Switching Frequency: 133K Hz. Circuit Topology: Forward circuit. Transient Response: Peak transient less than 50mV and recovers within 0.96mS after 25% load-change. Safety Standard: IEC 60950-1 Class I. Construction: Eurocard 3U X 9HP X 185mm CompactPCI format. |
Operating Temperature: -5 to +50 °C at full
load with specified air flow. Derates linearly to
50% at +60 °C. Storage Temperature: -40 to +85 °C. Temperature Coefficient: Typ. ±0.02% / °C. Cooling: At least 14CFM moving air is required to achieve full rating power 200W in a confined area. Power Density: 2.85 Watts/ Cubic Inch. |
NOTE:
Due to requests in market and advances in technology, specifications
subject to change without notification.
OUTPUT VOLTAGE / CURRENT RATINGS CHART
PENTA OUTPUT
MODEL NO. |
MAIN +VO1"@#=* |
AUX. +VO2"@#=*? |
AUX. +VO3"@#=*? |
AUX. +VO4"@#=*? |
AUX. VO5*"?% |
Min. Typ. Volt. Max. |
Min. Typ. Volt. Max. |
Min. Typ. Volt. Max. |
Min. Typ. Volt. Max. |
Min. Typ. Volt. Max. |
|
HAC203P- P033BCEI(E) |
1A 20A 3.3V 20A |
0.5A 9A 5V 9A |
0A 12A 2.5V 12A |
0A 17A 1.5V 17A |
1A 2A 12V 2A |
Symbol: """ OVP built-in. "@" Adjustable. "#" Remote
sensing. "≡" 3rd-wire Load Sharing. "%" Floating.
"*" Installed with Or-ing diode. "▲" Magnetic
Amplifier. "●" Installed with Post Regulator.
Remark: Peak load less than 60sec. with duty cycle <10%.
Max. load is the continuous operating load of each rail. But the
max. load of each rail can't be drawn from all outputs at the same time.
MECHANICAL DIMENSIONS: MM [INCHES] WEIGHT: 666.0 g (23.5 Oz.)

INPUT & OUTPUT CONNECTORS PIN ASSIGNMENT
PENTA OUTPUT |
||||||||||||||||
ASSIGNMENT |
V1 |
V2 |
V3 |
V4 |
DC COM |
+V5 |
-V5 |
V1 S |
V2 S |
V3 S |
V4 S |
-S |
V1 CS |
V2 CS |
V3 CS |
V4 CS |
CNTR &PIN # |
13,14,15,16, 17,18 |
1 |
2 |
3,4 |
5,6,7,8,9,10, 11,12,22,24 |
20 |
19 |
33 |
30 |
35 |
37 |
34 |
28 |
29 |
25 |
26 |
AC OUTPUT |
||||||||||||||||
ASSIGNMENT |
L |
N |
G |
|||||||||||||
CNTR &PIN # |
47 |
46 |
5 |
|||||||||||||
STATUS/CONTROL
ASSIGNMENT |
EN |
DEG |
INH |
FAL |
CRDEXEISIT_1 |
CRDEXEISIT_0 |
SLOT_ID0 |
SLOT_ID1 |
I2C_SDA |
I2C_SCL |
NC |
CNTR &PIN # |
27 |
38 |
39 |
42 |
31 |
32 |
40 |
41 |
43 |
44 |
21,23,36 |
Mating connector: PCIH47F400A1.