ON-BOARD AC/DC MODULAR POWER SUPPLIES

5 WATTS SINGLE & DUAL OUTPUT HAM05S & HAM05D

Latest Products

ON-BOARD UNIVERSAL INPUT AC-DC ENCAPSULATED MODULAR POWER SUPPLIES 5 WATTS SINGLE & DUAL OUTPUT HAM05S & HAM05D SERIES

ON-BOARD UNIVERSAL INPUT AC-DC ENCAPSULATED MODULAR POWER SUPPLIES 5 WATTS SINGLE & DUAL OUTPUT HAM05S & HAM05D SERIES

FEATURES:

ON-BOARD AC/DC MODULAR POWER SUPPLIES
UNIVERSAL AC INPUT RANGE
COMPACT IN SIZE
MEET UNIVERSAL SAFETY STANDARDS
EMI MEET CISPR PUB.22 / FCC CLASS B
CE MARKING COMPLIANCE

SPECIFICATION

INPUT SPECIFICATION

Input Voltage: 90-264Vac typical.
Input Frequency: 47-63 Hz. (50/60Hz.Nom.).
Input Current: 0.15A @115Vac./0.07A @230Vac.
Inrush Current: 32.5A peak @ 230Vac.
Input Fuse: Use external fuse. 1.0A/250Vac for the
primary fuse is suggested.
Dielectric Withstand: Meet IEC950.
3,000Vac-Output/Input.
1,500Vac-Input/GND.
500Vac-Output/GND.
EMI: Meet CISPR PUB.22 / FCC Class B.
Hold-up time: 20 mS @115Vac, 80mS @230Vac.
Earth Leakage: Less than 3.5mA @230Vac.

OUTPUT SPECIFICATION

Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart
Output Wattage: 5Watts typical.
Output Indicator: LED.
Line Regulation: Various with output voltages.
HAM05S ±0.1 % typical.
HAM05D ±0.5% typical.
Load Regulation: Various with output voltage.
HAM05S ±1.0% typical.
HAM05D ±2.0% typical.
Noise & ripple: 1.0% typical peak to peak.
OVP: Built-in on main output.
Adjustability: From -10% of main output till OVP.
Overload Protection (OLP):
Fully protected against output overload and short circuit.
OLP set at about 125-150% rating output wattage.
Consult the factory for OLP setting.

GENERAL SPECIFICATION

Efficiency: 64%-78% typical. (Various with output voltage).
Switching Frequency: 75K Hz.
Circuit Topology: Fixed Frequency Flyback circuit.
Transient Response: Typical peak deviation 250mV,
Recovery time < 3mS for a 25% load change.
Case: Impact resistant thermo-plastic enclosure.
Weight: 107.0g (3.77 Oz).
Power Density: 1.61 Watts. / Cubic inch.
Safety Standard: EN60950/ UL1950 Class I.
MTBF: 110,000 hours. Mil Std 217, 25°C.

Operating Temperature: -10 to +70°C range.
-10°C to +50°C full load without derating.
From +50°C, derating linearly to half load @+70°C.
(Refer to Derating Chart.)
Storage Temperature: -20°C to +85°C.
Temperature Coefficient: ± 0.03% /°C.
Humidity: Up to 95%RH, Non-condensing.
Cooling: Convection cooling for +50°C @ full load.
At least 100LFM moving air is recommended
for full load > +50°C in a confined area.
Commercial Grade only.

NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified. (2) Load Regulation measured from Full-Load (F-L) to Half-Load (H-L) at nominal input and others loaded at half load.

OUTPUT VOLTAGE / CURRENT RATINGS CHART

SINGLE OUTPUT

MODEL

VOL @ *
TYP. VOLT. PEAK

HAM05S-033130

1.30A 3.3V 1.59A

HAM05S-050100

1.00A 5.0V 1.20A

HAM05S-090060

0.60A 9.0V 0.72A

HAM05S-120045

0.45A 12.0V 0.54A

HAM05S-150036

0.36A 15.0V 0.43A

HAM05S-180030

0.30A 18.0V 0.36A

HAM05S-240022

0.22A 24.0V 0.26A

DUAL OUTPUT

MODEL

+VO1 @ *
TYP. VOLT. MAX

-VO2 ¦
TYP. VOLT. MAX

HAM05D-033064

0.64A +3.3V 0.73A

0.64A -3.3V 0.73A

HAM05D-050050

0.50A +5.0V 0.57A

0.50A -5.0V 0.57A

HAM05D-090030

0.30A +9.0V 0.34A

0.30A -9.0V 0.34A

HAM05D-120022

0.22A +12.0V 0.25A

0.22A -12.0V 0.25A

HAM05D-150018

0.18A +15.0V 0.20A

0.18A -15.0V 0.20A

Symbols: "*" OVP built-in. "@" Adjustable. "¦" Double Feedback.
Note: (1) Max. (maximum load) is the continuous operating load of each rail, but the max. load of each rail can not be drawn from all outputs at the same time. (2) Peak output, less than 60 Sec. with duty cycle <10%.

MECHANICAL DIMENSIONS: MM [INCHES] WEIGHT: 107.0g (3.77 Oz.)

MECHANICAL DIMENSIONS: MM [INCHES] WEIGHT: 107.0g (3.77 Oz.)

PIN ASSIGNMENT

PIN NO.

SINGLE

DUAL

PIN #1

AC-GROUND

AC-GROUND

PIN #2

AC-NEUTRAL

AC-NEUTRAL

PIN #3

AC-LINE

AC-LINE

PIN #4

+VO1

+VO1

PIN #5

NO PIN

DC-COM

PIN #6

DC-COM

-VO2

DERATING CHART

DERATING CHART