INPUT SPECIFICATION
Input Voltage: Auto-ranging 115(90-132) Vac and 230(180-264) VAC. Transient threshold 150Vac typical. (Option for dual input selectable)
Input Connector: See Pin assignment.
Input Frequency: 47-63Hz.
Inrush Current: Typ. 20A@115Vac, 40A@230Vac.
Input Current: 2.5A @115Vac, 1.1A @ 230Vac.
Dielectric Withstand: Meet IEC 60950-1.
EMI: Meet CISPR PUB. 22 & FCC Class B.
Hold-up Time: Typ. 22mS @115Vac, 27mS @230Vac.
Earth leakage: Typ. 0.5mA @230Vac.
Power Fail Signal: Installed.
Logic Inhibit: Optional in HIH100-1X and HVI100-2X dual output series.
|
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: Typ. 100 watts.
Output Connector: See pin assignment.
Line Regulation: Typ. 0.1%.
Load Regulation: Main VO1 typ. ±1.0%. Aux. VO2 typ. ±2.0%. (Magnetic Amp.) Aux. VO2 typ. ±5.0%. (Stacked-on.) Aux. VO3/VO4 typ. ±1.5%. (P.R.)
Noise & Ripple: Typ. 1.0% peak to peak.
OVP: Built-in at main VO1.
Adjustability: Available at VO1 & VO2.
Remote Sense: Optional in HIH100 & HVI100-2X.
Overload Protection (OLP): Fully protected against output overload and short circuit. OLP set at about 125-150% rating output wattage. Consult the factory for OLP setting.
|